THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF ZHONE TECHNOLOGIES,
INCORPORATED AND IS NOT TO BE DISCLOSED OR USED EXCEPT IN ACCORDANCE WITH
APPLICABLE AGREEMENTS.
Release Number: BS2600_ALL_02.05.17 BS2600_REVA_02.05.17 |
Date: April 30,
2009 |
|||
Release Type: GA
Release |
Country Type: N/A |
|||
Release History |
Affected Product
Models |
|||
Release |
Type |
Date |
Model |
Priority |
BS2600_ALL_020517 |
Released |
April 30, 2009 |
26xx / 42xx |
Minor |
BS2600_ALL_020516 |
Released |
March 16, 2009 |
26xx / 42xx |
Minor |
BS2600_ALL_020515 |
Released |
July 15, 2008 |
26xx / 42xx |
Major |
BS2600_ALL_020513 |
Released |
June 12, 2008 |
26xx / 42xx |
Minor |
BS2600_ALL_020511 |
Released |
November 12, 2007 |
26xx / 42xx |
Minor |
BS2600_ALL_020507 |
Released |
July 25, 2007 |
26xx / 42xx |
Minor |
BS2600_ALL_020505 |
Released |
May 17, 2007 |
26xx / 42xx |
Minor |
BS2600_ALL_020501 |
Released |
January 23, 2007 |
26xx / 42xx |
Minor |
Feature Enhancements
/ Functional Changes
Model to Shipping Software
Level Support – 26xx/42xx.
The following table lists the currently shipping models and associated loads for the 2600 and 4200 family.
Model |
Software |
Note |
Model |
Software |
Note |
Model |
Software |
Note |
|
2611 –
ReachDSL GigE uplink |
|||||||||
2611-A2-420 |
2.05.17 |
|
2611-A2-420-0HY |
2.05.15 |
|
2611-A2-420-0JP |
2.05.15 |
|
|
2611-A2-424 |
2.05.17 |
|
2611-A2-425 |
2.05.17 |
|
2611-A2-430 |
2.05.17 |
|
|
2611-A2-430-0HY |
2.05.15 |
|
2611-A2-434 |
2.05.17 |
|
2611-A2-435 |
2.05.17 |
|
|
2621 –
ADSL2+ GigE uplink |
|||||||||
2621-A3-420 |
2.05.17 |
|
2621-A3-423 |
2.05.17 |
|
2621-A3-424 |
2.05.17 |
|
|
2621-A3-425 |
2.05.17 |
|
2621-A3-430 |
2.05.17 |
|
2621-A3-433 |
2.05.17 |
|
|
2621-A3-434 |
2.05.17 |
|
2621-A3-435 |
2.05.17 |
|
2621-A3-430-0MT |
2.04.25 |
|
|
2631 –
ADSL2+ Annex B GigE uplink |
|||||||||
2631-A3-425 |
2.05.17 |
|
2631-A3-435 |
2.05.17 |
|
|
|
|
|
Model |
Software |
Note |
Model |
Software |
Note |
Model |
Software |
Note |
|
2671 –
SHDSL GigE uplink |
|||||||||
2671-A2-420 |
2.05.17 |
|
2671-A2-420-0HY |
2.05.15 |
|
2671-A2-424 |
2.05.17 |
|
|
2671-A2-425 |
2.05.17 |
|
|
|
|
|
|
|
|
2674 –
SHDSL T1/E1 MLPPP |
|||||||||
2674-A1-420 |
2.05.17 |
|
|
|
|
|
|
|
|
4211 –
ReachDSL ATM T1 |
|||||||||
4211-A1-530 |
2.03.06 |
|
|
|
|
|
|
|
|
4213 –
ReachDSL T1/E1 IMA |
|||||||||
4213-A1-522 |
2.03.06 |
|
4213-A1-530 |
2.03.06 |
|
4213-A1-532 |
2.03.06 |
|
|
4214 –
ReachDSL T1/E1 MLPPP |
|||||||||
4214-A1-530 |
2.05.17 |
|
|
|
|
|
|
|
|
4219 –
ReachDSL GigE uplink |
|||||||||
4219-A2-520 |
2.05.17 |
|
4219-A2-530 |
2.05.17 |
|
4219-A2-531 |
2.05.17 |
|
|
4223 – ADSL
T1/E1 IMA |
|||||||||
4223-A1-530 |
2.03.06 |
|
4223-A1-530-0VC |
2.03.06 |
|
4223-A1-532 |
2.03.06 |
|
|
4224 –
ADSL2+ T1/E1 MLPPP |
|||||||||
4224-A1-522 |
2.05.17 |
|
4224-A1-530 |
2.05.17 |
|
4224-A1-531 |
2.05.17 |
|
|
4229 –
ADSL2+ GigE uplink |
|||||||||
4229-A3-520 |
2.05.17 |
|
4229-A3-530 |
2.05.17 |
|
4229-A3-530-0MT |
2.03.11 |
|
|
4229-A3-531 |
2.05.17 |
|
|
|
|
|
|
|
|
4239 –
ADSL2+ Annex B GigE uplink |
|||||||||
4239-A3-520 |
2.05.17 |
|
4239-A3-532 |
2.05.17 |
|
|
|
|
|
4279 –
SHDSL GigE uplink |
|||||||||
4279-A2-520 |
2.05.17 |
|
|
|
|
|
|
|
|
Release Structure and
Identification
Filename |
Target Destination |
BS2600_REVA_020517.bin |
Binary for units
with Wintegra Revision A |
BS2600_ALL_020517.bin |
Management Download
– combined boot and application load. |
Note: DSLAMs running firmware versions prior to 2.1.0 will need to be upgraded with file BS2600_REVA_020517.bin first before upgrading to later builds. Otherwise the Download will fail.
DSLAMs with firmware 2.1.0 or later
use file BS2600_ALL_020517.bin
This
build may upgrade the unit's bootrom. Customers should not power cycle the unit
while a firmware switch is in progress. The bootrom update may take 5-10
minutes.
Resolved Customer Issues
in 02.05.17
Issue Identifier |
Issue Description |
75543 |
Unable to delete
static IP entry from security IP table Duplicate entries prevented static IP entries from being
deleted. |
76521 |
LEDs indicating
training not consistent. When disconnecting a loop in training mode, the LED would continue to flash. |
Unresolved Customer
Issues
Issue Identifier |
Issue Description |
67818 |
DSLAMs loss traffic after 2 months up time |
68132 |
DHCP filtering on DSL port |
System
Co-Requirements in 02.05.17
Model |
Description |
Incorporated Code Base |
4214-A1-xxx 4219-A2-xxx |
24 Port ReachDSL |
Reach DSP Release code 02040 |
2674-A1-xxx 4279-A2-xxx |
24 Port SHDSLbis Annex A |
Infineon DSP Release 0.9.3 |
4224-A1-xxx 4229-A3-xxx |
24 Port ADSLS2+ Annex A |
Broadcom DSP Release 06.04.08 |
4239-A3-xxx |
24 Port ADSLS2+ Annex B |
Broadcom DSP Release 06.04.08 |